Measured effects reported in the paper

What was changedWhereMeasuredEffect
Train ResNet-18 from scratch on Kinetics rather than the smaller video datasetsResNet-18 · Kinetics vs UCF-101, HMDB-51, ActivityNetvalidation accuracy: 40.1, 16.2, and 26.8%Mixed
Increase ResNet depth from 18 to 152 layers (ablation)3D ResNet · Kinetics validationAverage accuracy (Top-1 and Top-5): 66.1 -> 73.7Helped
Increase ResNet depth from 152 to 200 layers (ablation)3D ResNet · Kinetics validationAverage accuracy (Top-1 and Top-5): 73.7 -> 73.7No clear effect
Use a wider network rather than ResNet-152 (ablation)3D ResNet · Kinetics validationAverage accuracy (Top-1 and Top-5): 73.7 -> 74.7Helped
Introduce group-convolution cardinality in ResNet (ablation)3D ResNet · Kinetics validationAverage accuracy (Top-1 and Top-5): 73.7 -> 75.4Helped
Replace ResNet-200 blocks with pre-activation blocks (ablation)3D ResNet-200 · Kinetics validationAverage accuracy (Top-1 and Top-5): 73.7 -> 73.4Hurt
Use DenseNet connections instead of ResNet-style connections (ablation)3D CNN · Kinetics validationAverage accuracy (Top-1 and Top-5): 73.7 vs 70.8; 72.3Hurt
Increase input clip length from 16 to 64 frames (ablation)ResNeXt-101 · Kinetics testAverage accuracy (Top-1 and Top-5): 74.5 -> 78.4Helped
Pretrain ResNet-18 on Kinetics rather than training from scratch (ablation)ResNet-18 · UCF-101Top-1 accuracy: 42.4 -> 84.4Helped
Pretrain ResNet-18 on Kinetics rather than training from scratch (ablation)ResNet-18 · HMDB-51Top-1 accuracy: 17.1 -> 56.4Helped
Increase input clip length from 16 to 64 frames (ablation)ResNeXt-101 · UCF-101Top-1 accuracy: 90.7 -> 94.5Helped
Increase input clip length from 16 to 64 frames (ablation)ResNeXt-101 · HMDB-51Top-1 accuracy: 63.8 -> 70.2Helped