AI Paper Atlas

Research map / 3D vision / Depth and stereo

Off the Planckian Locus: Using 2D Chromaticity to Improve In-Camera Color

SaiKiran Tedla, Joshua Little, Hakki Karaimer, Michael S Brown

ECCV 2026 · 3D vision › Depth and stereo · approach: Neural light field and illumination imaging · 2 citations (OpenAlex)

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
use 2D chromaticity input instead of 1D CCT (ablation)CCM-MLP · Lightbox dataset (Pixel)mean angular error (deg): 4.11 -> 3.60Improved
use 2D chromaticity input instead of 1D CCT (ablation)NN · Lightbox dataset (Pixel)mean angular error (deg): 5.24 -> 4.30Improved
use 2D chromaticity input instead of 1D CCT (ablation)CCCNN · Lightbox dataset (Pixel)mean angular error (deg): 4.39 -> 4.00Improved
use 2D chromaticity input instead of 1D CCT (ablation)EXPINV · Lightbox dataset (Pixel)mean angular error (deg): 4.31 -> 3.84Improved
use 2D chromaticity input instead of 1D CCT (ablation)CCM-MLP(RP) · Lightbox dataset (Pixel)mean angular error (deg): 3.77 -> 3.27Improved
use xy chromaticity instead of raw 2D coordinates (ablation)CCM-MLP · In-the-wild (Pixel)mean angular error (deg): 4.02 -> 3.64Improved
add noise augmentation on input chromaticity (ablation)CCM-MLP (2D xy) · In-the-wild (Pixel)mean angular error (deg): 3.64 -> 3.32Improved
add noise augmentation on input chromaticity (ablation)CCM-MLP (2D xy) · Lightbox dataset (Pixel)mean angular error (deg): 3.53 -> 3.60Hurt
predict root-polynomial 3x6 mapping instead of linear 3x3 (ablation)CCM-MLP (2D xy, noise aug) · Lightbox dataset (Pixel)mean angular error (deg): 3.60 -> 3.27Improved
predict polynomial 3x9 mapping instead of linear 3x3 (ablation)CCM-MLP (2D xy, noise aug) · Lightbox dataset (Pixel)mean angular error (deg): 3.60 -> 3.67Hurt
use 2D chromaticity input instead of 1D CCT (ablation)CCM-MLP · NUS (Nikon)mean angular error (deg): 1.29 -> 1.28No clear effect
use 2D chromaticity input instead of 1D CCT (ablation)CCM-MLP · LSMI single-illuminant (Galaxy)mean angular error (deg): 3.77 -> 3.49Improved

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy