AI Paper Atlas

Research map / Vision-language and multimodal / Multimodal LLMs

Do Multimodal LLMs Understand Intraoral Dental Data? Dataset, Platform, and Baselines

Luca Lumetti, Federico Rizzo, Francesca Cremonini, Ettore Candeloro, Lombardo Luca, Costantino Grana, Federico Bolelli

ECCV 2026 · Vision-language and multimodal › Multimodal LLMs · approach: Interleaved image-text generation with MLLMs · 0 citations (OpenAlex)

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
use field-by-field (multi-turn) instead of one-shot prompting (ablation)IOS-Qwen (LoRA) · Occlusal report generation (IOS-only)Accuracy: 0.512 -> 0.632Improved
use field-by-field decoding instead of one-shot (ablation)IOS-Qwen (LoRA) · Occlusal report generation (IOS-only)ROUGE-L F1: 0.687 -> 0.763Improved
fine-tune the LLM with LoRA instead of freezing it (ablation)IOS-Qwen · Occlusal report generation (IOS-only)Accuracy: 0.411 -> 0.512Improved
pretrain PointTransformer with per-field classification heads (frozen LLM) (ablation)IOS-Qwen · Occlusal report generation (IOS-only)Accuracy: 0.372 -> 0.411Improved
pretrain the encoder with per-field heads (ablation)IOS-Qwen · Occlusal report generation (IOS-only)RadFact F1: 0.282 -> 0.308Improved
fine-tune LLM with LoRA instead of pretrained encoder with frozen LLM (ablation)IOS-Qwen · Occlusal report generation (IOS-only)RadFact F1: 0.308 -> 0.233Hurt
use per-field decoding costs about 9 times more inferences (ablation)IOS-Qwen · Occlusal report generation (IOS-only)inference cost: ~9xHurt
use IOS geometry model instead of best zero-shot IOP MLLMIOS-Qwen · Occlusal report generationAccuracy: 0.580 -> 0.632Improved
use medical-specific MedGemma-27B instead of MedGemma-4BMedGemma · Occlusal report generation (IOP-only)Accuracy: 0.514 -> 0.544Mixed
use the annotation platform with automatic pipelinesclinical workflow · Report time per patientseconds: 300 -> 60Improved

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy