Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| use Restormer backbone instead of U-Net (ablation) | SDUM T=6 · CMRxRecon2025 Regular Task 1 | PSNR (dB): 28.734 -> 32.090 | Improved |
| use 2 down-sampling layers instead of 4 (ablation) | SDUM T=6 · CMRxRecon2025 Regular Task 1 | PSNR (dB): 31.544 -> 32.090 | Improved |
| use 2 down-sampling layers instead of 1 (ablation) | SDUM T=6 · CMRxRecon2025 Regular Task 1 | PSNR (dB): Training failed | Improved |
| widen single cascade from 7.2M to 78.7M params (ablation) | SDUM T=1 · CMRxRecon2025 Regular Task 1 | PSNR (dB): 27.605 -> 28.978 | Improved |
| widen single cascade beyond 42.2M params (ablation) | SDUM T=1 · CMRxRecon2025 Regular Task 1 | PSNR (dB): 28.728 -> 28.978 | No clear effect |
| use per-cascade CSME instead of single shared CSME (ablation) | SDUM · CMRxRecon2025 Regular Task 1 | PSNR (dB): 29.694 -> 30.205 | Improved |
| use SWDC instead of simple learnable DC (ablation) | SDUM T=6 · CMRxRecon2025 Regular Task 1 | PSNR (dB): 31.661 -> 32.090 | Improved |
| use SWDC instead of non-sampling-aware weighted DC (ablation) | SDUM T=6 · CMRxRecon2025 Regular Task 1 | PSNR (dB): 31.787 -> 32.090 | Improved |
| add universal conditioning (ablation) | SDUM T=1 Iter=3 · CMRxRecon2025 Regular Task 1 | PSNR (dB): 29.693 -> 30.071 | Improved |
| use 3 cascades instead of 3 iterations of one cascade (ablation) | SDUM · CMRxRecon2025 Regular Task 1 | PSNR (dB): 30.071 -> 30.205 | Improved |
| increase unrolled depth from T=1 to T=18 | SDUM · CMRxRecon2025 Regular Task 1 | PSNR (dB): 28.73 -> 33.18 | Improved |
| increase depth from T=10 to T=18 | SDUM · CMRxRecon2025 Regular Task 1 | PSNR (dB): 32.54 -> 33.18 | Improved |
Closest papers by meaning
- Fast MRI for All: Bridging Access Gaps by Training without Raw Data (NeurIPS 2025 · similarity 0.86)
- Efficient Noise Calculation in Deep Learning-based MRI Reconstructions (ICML 2025 · similarity 0.85)
- A Unified Model for Compressed Sensing MRI Across Undersampling Patterns (CVPR 2025 · similarity 0.85)
- Progressive Divide-and-Conquer via Subsampling Decomposition for Accelerated MRI (CVPR 2024 · similarity 0.85)
- Null Space Matters: Range-Null Decomposition for Consistent Multi-Contrast MRI Reconstruction (AAAI 2024 · similarity 0.84)
- Breaking Information Isolation: Accelerating MRI via Inter-sequence Mapping and Progressive Masking (AAAI 2025 · similarity 0.84)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.