AI Paper Atlas

Research map / Image generation / Super-resolution

From Local Windows to Adaptive Candidates via Individualized Exploratory: Rethinking Attention for Image Super-Resolution

Chunyu Meng, Wei Long, Shuhang Gu

ECCV 2026 · Image generation › Super-resolution · approach: Perceptual and real-world SR · 0 citations (OpenAlex)

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
add propagation (two-hop neighbor exploration) to dilated attention (ablation)IET-light · Urban100 x4 (IET-light ablation)PSNR (dB): 26.17 -> 26.91Improved
add propagation to dilated attention (ablation)IET-light · Manga109 x4 (ablation)PSNR (dB): 30.58 -> 30.92Improved
add sparsification to dilated attention (ablation)IET-light · Urban100 x4 (IET-light ablation)PSNR (dB): 26.17 -> 26.28; FLOPs 180.4G -> 61.2GImproved
add sparsification to propagation (ablation)IET-light · Urban100 x4 (IET-light ablation)PSNR (dB): 26.91 -> 26.96; FLOPs 215.9G -> 68.9GImproved
add SF-FFN on top of propagation and sparsification (ablation)IET-light · Urban100 x4 (IET-light ablation)PSNR (dB): 26.96 -> 27.03Improved
add SF-FFN on top of propagation and sparsification (ablation)IET-light · Manga109 x4 (ablation)PSNR (dB): 31.05 -> 31.09Improved
increase propagation steps from 1 to 4 (ablation)IET-light · Urban100 x4 (IET-light ablation)PSNR (dB): 26.52 -> 27.03Improved
increase propagation steps from 4 to 5 (ablation)IET-light · Urban100 x4 (IET-light ablation)PSNR (dB): 27.03 -> 26.96No clear effect
increase dilation from 1 to 3 for train and inference (ablation)IET-light · Urban100 x4 (IET-light ablation)PSNR (dB): 26.86 -> 26.99Improved
train with d=2 and infer with d=3 instead of d=3 for both (ablation)IET-light · Urban100 x4 (IET-light ablation)PSNR (dB): 26.99 -> 27.03Improved
set k1/k2 ratio to 2 instead of 0.5 (ablation)IET-light · Urban100 x4 (IET-light ablation)PSNR (dB): 26.98 -> 27.03Improved
place SF-FFN after the last two blocks vs none (ablation)IET-light · Urban100 x4 (IET-light ablation)PSNR (dB): 26.96 -> 27.03Improved

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy