| What was changed | Where | Measured | Effect |
|---|---|---|---|
| add cost volume modulation (without confidence map) (ablation) | LiteFlowNet3 · Sintel final / KITTI 2015 (train) | AEE: 4.14 -> 4.09; 11.31 -> 11.01 | Improved |
| add flow field deformation on top of modulation, no confidence map (ablation) | LiteFlowNet3 · Sintel final / KITTI 2012 (train) | AEE: 4.09 -> 4.06 (Sintel final); 4.02 -> 4.06 (KITTI 2012) | Mixed |
| add confidence map to cost volume modulation (ablation) | LiteFlowNet3 · Sintel final / KITTI 2015 (train) | AEE: 4.09 -> 4.02; 11.01 -> 10.65 | Improved |
| add flow field deformation to modulation with confidence map (ablation) | LiteFlowNet3 · Sintel final / KITTI 2015 (train) | AEE: 4.02 -> 3.91; 10.65 -> 10.40 | Improved |
| add all modules (modulation, deformation, confidence map) (ablation) | LiteFlowNet3 · Sintel clean / KITTI 2012 (train) | AEE: 2.78 -> 2.59; 4.11 -> 3.88 | Improved |
| augment cost volume with features of I1 and flow field instead of modulation (ablation) | LiteFlowNet3 · Sintel final / KITTI 2015 (train) | AEE: 4.14 -> 4.20; 11.12 -> 11.30 | Hurt |
| use cost volume modulation instead of feature/flow augmentation (ablation) | LiteFlowNet3 · KITTI 2012 (train) | AEE: 4.28 -> 3.95 | Improved |
| use cost volume modulation instead of no augmentation (ablation) | LiteFlowNet3 · Sintel final / KITTI 2015 (train, FlyingChairs) | AEE: 4.14 -> 4.02; 11.12 -> 10.65 | Improved |
| add weight sharing to decoders and modules (LiteFlowNet3-S) (ablation) | LiteFlowNet3 · model size | parameters (M): 7.5M -> 5.2M | Improved |
| use LiteFlowNet3 instead of LiteFlowNet2 | LiteFlowNet2 · Sintel clean (test) unmatched | AEE: 20.64 -> 18.08 | Improved |
| use LiteFlowNet3 instead of LiteFlowNet2 | LiteFlowNet2 · Sintel clean (test) | AEE: 3.48 -> 2.99 | Improved |
Closest papers by meaning
- LiteFlowNet: A Lightweight Convolutional Neural Network for Optical Flow Estimation (CVPR 2018 · similarity 0.93)
- A Lightweight Optical Flow CNN —Revisiting Data Fidelity and Regularization (TPAMI 2020 · similarity 0.93)
- Rethinking Optical Flow From Geometric Matching Consistent Perspective (CVPR 2023 · similarity 0.89)
- Learning Optical Flow From Still Images (CVPR 2021 · similarity 0.89)
- Unsupervised Deep Learning for Optical Flow Estimation (AAAI 2017 · similarity 0.88)
- FlowNet 2.0: Evolution of Optical Flow Estimation With Deep Networks (CVPR 2017 · similarity 0.88)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.