AI Paper Atlas

Research map / Label-efficient and robust learning / Semi-supervised learning

Negative Pseudo Labeling using Class Proportion for Semantic Segmentation in Pathology

Hiroki Tokunaga, Brian Kenji Iwana, Yuki Teramoto, Akihiko Yoshizawa, Ryoma Bise

ECCV 2020 · Label-efficient and robust learning › Semi-supervised learning · approach: Semi-supervised medical segmentation · 23 citations (OpenAlex)

Read the paper

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
add negative pseudo labels and adaptive positive threshold (full method)Pseudo Labeling · Lung adenocarcinoma subtype segmentation (5-fold CV)mIoU: 0.420 -> 0.435Improved
use weak proportion labels with pseudo labeling vs supervised onlySupervised MobileNetV2 · Lung adenocarcinoma subtype segmentation (5-fold CV)mIoU: 0.373 -> 0.435Improved
use proposed method instead of ICT/Mean Teachers/mixup/VATSSL baselines · Lung adenocarcinoma subtype segmentation (5-fold CV)mIoU: 0.270 to 0.324 -> 0.435Improved
standard SSL methods using unlabeled data vs supervised onlyICT, Mean Teachers, VAT · Lung adenocarcinoma subtype segmentation (5-fold CV)mIoU: 0.373 -> 0.289Hurt
replace fixed 0.95 threshold with adaptive positive threshold (ablation)Pseudo Labeling · Lung adenocarcinoma subtype segmentation (5-fold CV)mIoU: 0.420 -> 0.412Hurt
add single negative labeling to adaptive positive labeling (ablation)Adaptive Pseudo Labeling · Lung adenocarcinoma subtype segmentation (5-fold CV)mIoU: 0.412 -> 0.426Improved
add multi negative labeling to adaptive positive labeling (ablation)Adaptive Pseudo Labeling · Lung adenocarcinoma subtype segmentation (5-fold CV)mIoU: 0.412 -> 0.435Improved
use multi negative instead of single negative labeling (ablation)Adaptive + negative labeling · Lung adenocarcinoma subtype segmentation (5-fold CV)mIoU: 0.426 -> 0.435Improved
add positive pseudo labels to single negative labeling (ablation)Negative labeling only · Lung adenocarcinoma subtype segmentation (5-fold CV)mIoU: 0.348 -> 0.426Improved
add positive pseudo labels to multi negative labeling (ablation)Negative labeling only · Lung adenocarcinoma subtype segmentation (5-fold CV)mIoU: 0.336 -> 0.435Improved
negative pseudo labeling alone vs supervised (ablation)Single negative label only · Lung adenocarcinoma subtype segmentation (5-fold CV)mIoU: 0.373 -> 0.348Hurt

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy