AI Paper Atlas

Research map / 3D vision / Human pose estimation

Whole-Body Human Pose Estimation in the Wild

Sheng Jin, Lumin Xu, Jin Xu, Can Wang, Wentao Liu, Chen Qian, Wanli Ouyang, Ping Luo

ECCV 2020 · 3D vision › Human pose estimation · approach: Heatmap and coordinate pose encoding · 304 citations (OpenAlex)

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
train on all 133 whole-body keypoints instead of 17 body keypoints onlyHRNet · COCO-WholeBody body keypointsmAP: -9.9% mAPHurt
train on all 133 whole-body keypoints instead of 17 body keypoints onlyAE · COCO-WholeBody body keypointsmAP: -17.7% mAPHurt
train on all 133 whole-body keypoints instead of 17 body keypoints onlyPAF · COCO-WholeBody body keypointsmAP: -14.3% mAPHurt
two-stage zoom-in decoupling body and face/hand estimationZoomNet · COCO-WholeBody body keypointsmAP: -1.5% mAPMixed
replace one-stage HRNet with zoom-in ZoomNet (same HRNet-W32 backbone)HRNet · COCO-WholeBodywhole-body mAP: 10.9% mAP and 13.8% mARImproved
use ground-truth face/hand boxes instead of predicted boxes (ablation)ZoomNet · COCO-WholeBodyface/hand/whole-body mAP: 19.6%, 8.4% and 23.6%Improved
add joint training of BodyNet and Face/HandHead instead of reusing features (ablation)ZoomNet · COCO-WholeBodyface AP: 0.609 -> 0.623Improved
add joint training of BodyNet and Face/HandHead instead of reusing features (ablation)ZoomNet · COCO-WholeBodyhand AP: 0.393 -> 0.401Improved
use fully independent face/hand detectors instead of joint training (ablation)ZoomNet · COCO-WholeBodywhole-body AP: 0.541 -> 0.543No clear effect
pretrain on WholeBody-Hand before fine-tuning on Panoptic (ablation)HRNetV2-W18 · CMU Panoptic handEPE: 7.49 -> 7.00Improved
fine-tune on 300W after training on WholeBody-Face (ablation)HRNetV2-W18 · 300W challengingNME: 5.15 -> 4.73Improved
pretrain on Panoptic then fine-tune on WholeBody-Hand (ablation)HRNetV2-W18 · WBHNME: 6.66 -> 6.49Improved

Earlier methods this paper compares with

Named baselines from earlier accepted papers in this paper's results tables: better than 1 of 1 on most shared results.

Matched by method name in results tables read by AI. Authors' own tables tend to favour the newer method, and a comparison can be missed when a method is renamed.

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy