AI Paper Atlas

Research map / Label-efficient and robust learning / Zero-/few-shot and meta-learning

TAFSSL: Task-Adaptive Feature Sub-Space Learning for few-shot classification

Moshe Lichtenstein, Prasanna Sattigeri, Rogerio Feris, Raja Giryes, Leonid Karlinsky

ECCV 2020 · Label-efficient and robust learning › Zero-/few-shot and meta-learning · approach: Alignment-based few-shot metric learning · 77 citations (OpenAlex)

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
add ICA task-adaptive sub-space projection (ablation)Simple shot NN · miniImageNet 1-shot (transductive)accuracy (%): 64.30 -> 72.10Improved
add PCA task-adaptive sub-space projection (ablation)Simple shot NN · tieredImageNet 1-shot (transductive)accuracy (%): 71.26 -> 80.07Improved
use ICA instead of PCA for sub-space (ablation)TAFSSL · miniImageNet 1-shot (transductive)accuracy (%): 70.53 -> 72.10Improved
add Bayesian K-Means after ICA (ablation)ICA · miniImageNet 1-shot (transductive)accuracy (%): 72.10 -> 75.79Improved
add Mean-Shift Propagation after ICA (ablation)ICA · miniImageNet 1-shot (transductive)accuracy (%): 72.10 -> 77.06Improved
add ICA sub-space before clustering (ablation)MSP · tieredImageNet 1-shot (transductive)accuracy (%): 76.01 -> 84.29Improved
add Bayesian K-Means after ICA (ablation)ICA · miniImageNet 5-shot (transductive)accuracy (%): 81.85 -> 82.83No clear effect
add BKM clustering without sub-space projection (ablation)Simple shot NN · tieredImageNet 5-shot (transductive)accuracy (%): 86.59 -> 85.67Hurt
increase unlabeled samples from 30 to 100 (ablation)ICA + MSP · miniImageNet 1-shot (semi-supervised)accuracy (%): 78.55 -> 80.11Improved
use DenseNet backbone instead of Conv-4 (ablation)PCA + MSP · miniImageNet 1-shot (transductive)accuracy (%): 56.63 -> 76.31Improved
increase query set skew up to R = 50 (ablation)ICA-based TAFSSL · miniImageNet and tieredImageNet transductiveaccuracy (%): at most 1% loss at R = 50No clear effect
add distracting classes to unlabeled data (0 to 7) (ablation)ICA-based TAFSSL · semi-supervised miniImageNetaccuracy (%): about 8% gap keptNo clear effect

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy