Research map / 3D vision / Depth and stereo
Efficient Non-Line-of-Sight Imaging from Transient Sinograms
Mariko Isogawa, Dorian Chan, Ye Yuan, Kris Kitani, Matthew O’Toole
Read the paperCheck your idea against 137,217 papers
AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| use circular confocal scan (C2NLOS) instead of 64x64 confocal grid scan for localization | NLOS imaging · Capture time | capture time: 1.6% of the capture time; 2 Hz -> 130 Hz | Improved |
| replace LCT with C2NLOS Hough voting for single-scatterer localization | scatterer localization · Scatterer localization (one scatterer) | time (sec): 6.86 -> 0.50 | Improved |
| replace FK with C2NLOS Hough voting for single-scatterer localization | scatterer localization · Scatterer localization (one scatterer) | time (sec): 25.45 -> 0.50 | Improved |
| replace FK with C2NLOS for single-scatterer localization (z-axis error) | scatterer localization · Scatterer localization (one scatterer) | mean error z-axis: 0.17 -> 0.93 | Hurt |
| replace LCT with C2NLOS for two-scatterer localization (z-axis error) | scatterer localization · Scatterer localization (two scatterers) | mean error z-axis: 1.40 -> 7.37 | Hurt |
| replace LCT with C2NLOS for two-scatterer localization (time) | scatterer localization · Scatterer localization (two scatterers) | time (sec): 6.92 -> 0.52 | Improved |
| use inverse Radon reconstruction instead of LCT for 2D plane imaging | 2D plane imaging · 2D plane imaging | speedup: 50x speedup over LCT; SSIM slightly worse | Mixed |
| apply ramp (Ram-Lak) filter in inverse Radon reconstruction (ablation) | inverse Radon 2D imaging · 2D reconstruction of non-spherical objects | artifacts | Hurt |
| use C2NLOS with 360 samples instead of LCT/FK with 360 grid samples | 2D reconstruction · Fixed budget of 360 samples | reconstruction resolution: 19 x 19 -> 360 x 360 | Improved |
Closest papers by meaning
- Virtual Scanning: Unsupervised Non-line-of-sight Imaging from Irregularly Undersampled Transients (NeurIPS 2024 · similarity 0.90)
- Analysis of Feature Visibility in Non-Line-Of-Sight Measurements (CVPR 2019 · similarity 0.90)
- Steady-State Non-Line-Of-Sight Imaging (CVPR 2019 · similarity 0.90)
- Acoustic Non-Line-Of-Sight Imaging (CVPR 2019 · similarity 0.88)
- Deep Non-line-of-sight Imaging from Under-scanning Measurements (NeurIPS 2023 · similarity 0.88)
- Non-Line-of-Sight Imaging With Signal Superresolution Network (CVPR 2023 · similarity 0.88)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.
