Measured effects reported in the paper

What was changedWhereMeasuredEffect
add Spatial Module (SM) to Context Module (ablation)DFvT-S · ImageNet-1K val (ablation)top-1 accuracy (%): 77.0 -> 77.5Improved
add DANE fusion to CM+SM (ablation)DFvT-S · ImageNet-1K val (ablation)top-1 accuracy (%): 77.5 -> 78.3Improved
add convolutional information flow to pre-SA fusion (ablation)DFvT-S · ImageNet-1K val (ablation)top-1 accuracy (%): 72.2 -> 78.3Improved
add max-pooling information flow to pre-SA fusion (ablation)DFvT-S · ImageNet-1K val (ablation)top-1 accuracy (%): 78.1 -> 78.3Improved
replace SUM fusion by DANE (ablation)DFvT-S · ImageNet-1K val (ablation)top-1 accuracy (%): 77.5 -> 78.3Improved
replace SE fusion by DANE (ablation)DFvT-S · ImageNet-1K val (ablation)top-1 accuracy (%): 78.0 -> 78.3Improved
reverse DANE (channel and spatial attention swapped between CM and SM) (ablation)DFvT-S · ImageNet-1K val (ablation)top-1 accuracy (%): 78.3 -> 78.1Hurt
downsample input feature map before SA (Downsampled ViT vs baseline ViT) (ablation)window-SA ViT · ImageNet-1K val (design study)top-1 accuracy (%): 74.7 -> 71.9Hurt
add parallel convolution path to Downsampled ViT (ablation)Downsampled ViT · ImageNet-1K val (design study)top-1 accuracy (%): 71.9 -> 76.9Improved
use DFvT-S design instead of Parallel ViT (ablation)Parallel ViT · ImageNet-1K val (design study)throughput (imgs/s): 1843.3 -> 2203.3Improved
downsample before SA instead of baseline ViT (ablation)window-SA ViT · ImageNet-1K val (design study)throughput (imgs/s): 1168.2 -> 3091.5Improved

Earlier methods this paper compares with

Named baselines from earlier accepted papers in this paper's results tables: better than 2 of 2 on most shared results.

Matched by method name in results tables read by AI. Authors' own tables tend to favour the newer method, and a comparison can be missed when a method is renamed.

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy