AI Paper Atlas

Research map / 3D vision / Face and shape

REALY: Rethinking the Evaluation of 3D Face Reconstruction

Zenghao Chai, Haoxian Zhang, Jing Ren, Di Kang, Zhengzhuo Xu, Xuefei Zhe, Chun Yuan, Linchao Bao

ECCV 2022 · 3D vision › Face and shape · approach: 3D morphable face model regression · 55 citations (OpenAlex)

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
use region-wise bICP instead of global gICP for correspondence (ablation)evaluation pipeline · nn-map error, noseerror (mm): 2.882 -> 0.670Improved
use region-wise bICP instead of global gICP for correspondence (ablation)evaluation pipeline · nn-map error, moutherror (mm): 1.699 -> 0.407Improved
use region-wise bICP instead of global gICP for correspondence (ablation)evaluation pipeline · nn-map error, foreheaderror (mm): 0.707 -> 0.520Improved
use region-wise bICP instead of global gICP for correspondence (ablation)evaluation pipeline · nn-map error, cheekerror (mm): 1.219 -> 0.105Improved
add bidirectional step to region-wise rICP (ablation)evaluation pipeline · nn-map error, noseerror (mm): 0.706 -> 0.670Improved
add bidirectional step to region-wise rICP (ablation)evaluation pipeline · nn-map error, cheekerror (mm): 0.107 -> 0.105No clear effect
align with region-wise rICP instead of gICP (ablation)evaluation pipeline · alignment distance to S_L, nose-modified shape, nose regione (mm/10): 40.490 -> 8.376Improved
evaluate with bICP instead of gICPface reconstruction methods · REALYbest-method rankingMixed
use HIFI3D^A instead of HIFI3D basis in RGB-D fitting3DMM fitting · REALY RGB-D fittingbICP error all (mm): 1.093 -> 0.972Improved
use the new 3DMM basis instead of HIFI3D^A3DMM fitting · REALY RGB-D fittingbICP error all (mm): 0.972 -> 0.878Improved
use RGB-D instead of RGB fittingHIFI3D^A · REALYbICP error all (mm): 2.167 -> 0.972Improved
use RGB-D instead of RGB fittingFS · REALYbICP error all (mm): 2.386 -> 1.927Improved

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy