Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| use PressureVisionNet instead of 3D pose baseline | hand pressure estimation · PressureVisionDB test (6 unseen participants) | contact IoU: 13.0% -> 55.8% | Improved |
| use PressureVisionNet instead of 3D pose baseline | hand pressure estimation · PressureVisionDB test (6 unseen participants) | temporal accuracy: 78.1% -> 96.2% | Improved |
| add temporal input (4 frames) (ablation) | PressureVisionNet · PressureVisionDB test (6 unseen participants) | volumetric IoU: 41.3% -> 43.1% | Improved |
| add temporal input (4 frames) (ablation) | PressureVisionNet · PressureVisionDB test (6 unseen participants) | MAE: 39.9 Pa -> 39.4 Pa | Improved |
| use RGB color instead of monochrome (ablation) | PressureVisionNet · PressureVisionDB test (6 unseen participants) | volumetric IoU: 37.7% -> 41.3% | Improved |
| use RGB color instead of monochrome (ablation) | PressureVisionNet · PressureVisionDB test (6 unseen participants) | contact IoU: 53.2% -> 55.8% | Improved |
| increase input resolution from 15x12 to 480x384 (ablation) | PressureVisionNet · PressureVisionDB test (6 unseen participants) | volumetric IoU: 11.7% -> 41.3% | Improved |
| increase input resolution from 120x96 to 480x384 (ablation) | PressureVisionNet · PressureVisionDB test (6 unseen participants) | volumetric IoU: 39.5% -> 41.3% | Mixed |
| increase input resolution from 240x192 to 480x384 (ablation) | PressureVisionNet · PressureVisionDB test (6 unseen participants) | volumetric IoU: 39.3% -> 41.3% | Improved |
| classification over 9 log bins instead of direct regression (ablation) | PressureVisionNet · PressureVisionDB test (6 unseen participants) | pressure accuracy | Improved |
| dark vs light skin tone | PressureVisionNet · PressureVisionDB skin tone (5-fold CV) | volumetric IoU: 38.5% -> 39.0% | No clear effect |
| palm press instead of single-finger press | PressureVisionNet · PressureVisionDB test (6 unseen participants) | volumetric IoU: 59.4% -> 33.2% | Hurt |
Closest papers by meaning
- HOPE: Hand-Object Pressure Estimation from Monocular Videos (NeurIPS 2026 · similarity 0.91)
- EgoPressure: A Dataset for Hand Pressure and Pose Estimation in Egocentric Vision (CVPR 2025 · similarity 0.90)
- Posture-Informed Muscular Force Learning for Robust Hand Pressure Estimation (NeurIPS 2024 · similarity 0.88)
- MotionPRO: Exploring the Role of Pressure in Human MoCap and Beyond (CVPR 2025 · similarity 0.87)
- ContactPose: A Dataset of Grasps with Object Contact and Hand Pose (ECCV 2020 · similarity 0.87)
- BodyMAP - Jointly Predicting Body Mesh and 3D Applied Pressure Map for People in Bed (CVPR 2024 · similarity 0.85)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.