AI Paper Atlas

Research map / 3D vision / Human pose estimation

Learning to Fit Morphable Models

Vasileios Choutas, Federica Bogo, Jingjing Shen, Julien Valentin

ECCV 2022 · 3D vision › Human pose estimation · approach: Human shape and pose regression · 16 citations (OpenAlex)

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
replace LGD update rule with the proposed weighted gradient/network updateLGD · 3DPWPA-MPJPE (mm): 55.9 -> 53.9Improved
add GRU memory and architecture changesOurs LGD + update rule · 3DPWPA-MPJPE (mm): 53.9 -> 52.2Improved
add gradient descent term to network update (ablation)Neural fitter · SMPL-H HMD ablation (half-space)V2V head (mm): 14.7 -> 3.2Improved
add gradient descent term to network update (ablation)Neural fitter · SMPL-H HMD ablation (half-space)V2V full body (mm): 53.8 -> 49.9Improved
use per-step network weights instead of shared (ablation)Neural fitter · SMPL-H HMD ablation (half-space)V2V full body (mm): 52.3 -> 49.9Improved
use per-step network weights instead of shared (ablation)Neural fitter · SMPL-H HMD ablation (half-space)ground penetration (mm): 18.2 -> 15.5Improved
use GRU instead of ResNet feed-forward network (ablation)Neural fitter · SMPL-H HMD ablation (half-space)V2V full body (mm): 65.3 -> 53.6Improved
add second GRU layer (ablation)Neural fitter · SMPL-H HMD ablation (half-space)V2V full body (mm): 53.6 -> 49.9Improved
learn the step size gamma instead of constant 1e-4 (ablation)Neural fitter · SMPL-H HMD ablation (half-space)V2V full body (mm): 51.9 -> 49.9Improved
use vector instead of scalar lambda and gamma (ablation)Neural fitter · 3DPWPA-MPJPE (mm): 52.8 -> 52.3Improved
share network for lambda and gamma (ablation)Neural fitter · 3DPWPA-MPJPE (mm): 52.3 -> 52.2Improved
replace GRU with LSTM (ablation)Neural fitter · not reportednot reportedNo clear effect

Earlier methods this paper compares with

Named baselines from earlier accepted papers in this paper's results tables: better than 2 of 2 on most shared results.

Matched by method name in results tables read by AI. Authors' own tables tend to favour the newer method, and a comparison can be missed when a method is renamed.

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy