Research map / 3D vision / Depth and stereo
Camera Auto-Calibration from the Steiner Conic of the Fundamental Matrix
Yu Liu, Hui Zhang
Read the paperCheck your idea against 137,217 papers
AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| use Steiner conic method instead of GA-PSO with 3 images | full auto-calibration · Real camera (Nikon D300s) | fx relative error: 9.22% -> 4.45% | Improved |
| use Steiner conic method instead of GA-PSO with 6 images | full auto-calibration · Real camera (Nikon D300s) | fx relative error: 5.22% -> 3.18% | Improved |
| use Steiner conic method instead of GA-PSO with 10 images | full auto-calibration · Real camera (Nikon D300s) | fx relative error: 4.74% -> 3.41% | Improved |
| use Steiner conic method instead of GA-PSO with 10 images | full auto-calibration · Real camera (Nikon D300s) | u0 relative error: 7.92% -> 5.18% | Improved |
| use Steiner conic method instead of GA-PSO with 6 images | full auto-calibration · Real camera (Nikon D300s) | fy relative error: 7.16% -> 5.28% | Improved |
| increase number of images from 3 to 10 | known principal point calibration · Real camera (Nikon D300s) | fx relative error: 6.10% -> 4.58% | Improved |
| increase number of images from 3 to 10 | full auto-calibration · Real camera (Nikon D300s) | fx relative error: 4.45% -> 3.41% | Improved |
| increase number of images from 3 to 10 | full auto-calibration · Real camera (Nikon D300s) | v0 relative error: 8.89% -> 5.01% | Improved |
| estimate principal point too (full vs known principal point) | Steiner conic calibration · Synthetic cube, noise 1.0 px | fx relative error: 0.02% -> 0.13% | Hurt |
| estimate principal point too (full vs known principal point) | Steiner conic calibration · Synthetic cube, noise 1.0 px | fy relative error: 0.17% -> 0.33% | Hurt |
| estimate skew directly | Steiner conic calibration · Real camera (Nikon D300s) | skew s | No clear effect |
| increase number of images up to six | Steiner conic calibration · Synthetic cube, noise 1.0 px | relative error of intrinsics | Improved |
Closest papers by meaning
- Necessary and Sufficient Polynomial Constraints on Compatible Triplets of Essential Matrices (IJCV 2020 · similarity 0.86)
- Self-Calibration of Cameras with Euclidean Image Plane in Case of Two Views and Known Relative Rotation Angle (ECCV 2018 · similarity 0.85)
- Unbiased Estimator for Distorted Conics in Camera Calibration (CVPR 2024 · similarity 0.84)
- Minimal Perspective Autocalibration (CVPR 2024 · similarity 0.83)
- Camera Resection from Known Line Pencils and a Radially Distorted Scanline (CVPR 2025 · similarity 0.83)
- Robust Self-calibration of Focal Lengths from the Fundamental Matrix (CVPR 2024 · similarity 0.83)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.
