AI Paper Atlas

Research map / Label-efficient and robust learning / Semi-supervised learning

Semi-supervised Segmentation of Histopathology Images with Noise-Aware Topological Consistency

Meilong Xu, Xiaoling Hu, Saumya Gupta, Shahira Abousamra, Chao Chen

ECCV 2024 · Label-efficient and robust learning › Semi-supervised learning · approach: Semi-supervised medical segmentation · 11 citations (OpenAlex)

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
add signal topology consistency loss only (ablation)TopoSemiSeg on CRAG 20% · CRAG (20% labeled)Betti Matching Error: 12.125 -> 10.150Improved
add both signal consistency and noisy topology removal losses (ablation)TopoSemiSeg on CRAG 20% · CRAG (20% labeled)Betti Matching Error: 12.125 -> 8.575Improved
decompose persistence diagrams into signal and noise (phi 0.7) instead of direct matching (phi 0) (ablation)TopoSemiSeg · CRAG (20% labeled)Betti Matching Error: 14.025 -> 8.575Improved
retain noise and remove signal instead of the proposed decomposition (ablation)TopoSemiSeg · CRAG (20% labeled)Betti Matching Error: 8.575 -> 21.325Hurt
vary persistence threshold phi from 0.5 to 0.9 (ablation)TopoSemiSeg · CRAG (20% labeled)Betti Matching Error: 8.575 to 10.150No clear effect
add topology loss to PSPNet backbone (ablation)PSPNet · CRAG (20% labeled)Betti Matching Error: 70.625 -> 44.150Improved
EMA decay 0.9999 or 0.99 instead of 0.999 (ablation)TopoSemiSeg · CRAG (20% labeled)Betti Matching Error: 8.575 -> 11.850Hurt
increase topology loss weight lambda_U2 to 0.01 (ablation)TopoSemiSeg · CRAG (20% labeled)Dice_Obj: 0.898 -> 0.873Hurt
add supervised plus unsupervised topology losses on 100% labeled data (ablation)Fully-supervised UNet++ · CRAG (100% labeled)Dice_Obj: 0.928 -> 0.913Hurt
topology consistency on 20% labels vs supervised TopoLossTopoSemiSeg · CRAG (20% labeled)Betti Matching Error: 19.925 -> 8.575Improved
pixel-wise accuracy vs XNet/URPC on some settingsTopoSemiSeg · MoNuSeg (20% labeled)Accuracy: 0.909 (URPC) vs 0.908No clear effect

Earlier methods this paper compares with

Named baselines from earlier accepted papers in this paper's results tables: better than 2 of 2 on most shared results.

Matched by method name in results tables read by AI. Authors' own tables tend to favour the newer method, and a comparison can be missed when a method is renamed.

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy