AI Paper Atlas

Research map / Probabilistic and scientific modeling / Molecules and proteins

This Probably Looks Exactly Like That: An Invertible Prototypical Network

Zachariah Carmichael, Timothy P Redgrave, Daniel Gonzalez Cedre, Walter Scheirer

ECCV 2024Probabilistic and scientific modeling › Molecules and proteinsapproach: Probabilistic embeddings and relational inference6 citations (OpenAlex)

University of Notre Dame

Read the paperPlace an idea next to itCheck your own paper ↗

13measured effects
5improved
2no clear effect
4hurt
2mixed

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
learn prototypes as latent distributions with a normalizing flow instead of point prototypesProtoFlow · CIFAR-10accuracy: 84.9 -> 91.54Improved
use ProtoFlow instead of IB-INN (gamma=1) among flow-based generative classifiersProtoFlow · CIFAR-100accuracy: 57.43 -> 69.80Improved
ProtoFlow versus FlowGMM on MNISTProtoFlow · MNISTaccuracy: 99.63 (FlowGMM) vs 99.36Hurt
ProtoFlow versus prototype-free ProtoPNet on CUB-200-2011ProtoFlow · CUB-200-2011accuracy: 76.42 -> 50.58Hurt
prune prototypes with weights below an Otsu threshold (89.9% pruned) (ablation)ProtoFlow · CIFAR-100accuracy: 69.80 -> 69.63No clear effect
prune 54.0% of prototypes (ablation)ProtoFlow · MNISTaccuracy: 99.39 -> 96.26Hurt
add consistency regularization lossProtoFlow · CIFAR-10sample quality of prototype distributionsMixed
train with SGD instead of expectation maximization for the Gaussian mixturesProtoFlow · classificationaccuracyImproved
initialize prototype means with K-means instead of randomProtoFlow · CIFAR-10final accuracyNo clear effect
increase Monte Carlo samples of the DenseFlow forward passProtoFlow · CIFAR-10accuracy, BPD, calibration: plateau near 25 samples, stable near 100Improved
add ELBO loss term (ablation)ProtoFlow · CIFAR-10 (11 epochs)bits per dimension: 34.17 -> 6.618Improved
add ELBO loss term (ablation)ProtoFlow · CIFAR-10 (11 epochs)accuracy: 69.72 -> 61.70Hurt

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy