Measured effects reported in the paper

What was changedWhereMeasuredEffect
train with human pose labels (pose supervision) (ablation)PoseSOR · ASSR (ablation setting)SA-SOR: 0.665 -> 0.673Improved
add pose aggregation into salient object queries (ablation)PoseSOR PAI module · ASSR (ablation setting)SA-SOR: 0.667 -> 0.673Improved
add scene tokens (ablation)PoseSOR PAI module · ASSR (ablation setting)SA-SOR: 0.670 -> 0.673Improved
add instance-specific features feat_ins (ablation)PoseSOR PAI module · ASSR (ablation setting)SA-SOR: 0.669 -> 0.673Improved
use pose knowledge on images with no humans (ablation)PoseSOR · ASSR images with no humansSA-SOR: 0.596 -> 0.584No clear effect
use pose knowledge on images with at least one human (ablation)PoseSOR · ASSR images with at least 1 humanSA-SOR: 0.709 -> 0.728Improved
use pose knowledge on images with two humans vs one (ablation)PoseSOR · ASSR images by human countSA-SOR: 1 human: 0.717 -> 0.722; 2 humans: 0.719 -> 0.745Improved
combine directional cues learning and rankings inference in PDR (ablation)PoseSOR PDR module · ASSR (ablation setting)SA-SOR: 0.666 -> 0.673Improved
add directional cues learning alone, without rankings inference (ablation)PoseSOR PDR module · ASSR (ablation setting)SA-SOR: 0.666 -> 0.661Hurt
increase shifting directions from 1 to 8 (ablation)PoseSOR PDR module · ASSR (ablation setting)SA-SOR: 0.670 -> 0.673Improved
increase shifting directions from 4 to 8 (ablation)PoseSOR PDR module · ASSR (ablation setting)SA-SOR: 0.673 -> 0.673No clear effect

Later papers that compared with this method

2 later accepted papers report PoseSOR as a baseline in their results tables; 2 of them report a better number on most of the results they share with it.

Matched by method name in results tables read by AI. Authors' own tables tend to favour the newer method, and a comparison can be missed when a method is renamed.

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy