Measured effects reported in the paper

What was changedWhereMeasuredEffect
add early-stage oscillation encouragement and decoupled thresholds/levels (expand solution space) (ablation)LSQ, ResNet-50 W2/A2 · ImageNet valtop-1 accuracy (%): 73.7 -> 75.2Improved
add delayed weight oscillation suppression (ablation)LSQ, ResNet-50 W2/A2 · ImageNet valtop-1 accuracy (%): 73.7 -> 75.6Improved
combine expanded solution space and delayed suppression (ablation)LSQ, ResNet-50 W2/A2 · ImageNet valtop-1 accuracy (%): 73.7 -> 76.3Improved
allow oscillation early instead of suppressing it throughout training (ablation)LSQ toy example · toy 2-bit problemminimum loss: 26.2 -> 5.6Improved
suppress oscillation only in final stage versus throughout (ablation)LSQ toy example · toy 2-bit problemminimum loss: 26.2 -> 16.7Improved
add AOQ to LSQ on 2-bit ResNet-18LSQ · ImageNet val ResNet-18 W2/A2top-1 accuracy (%): 67.6 -> 69.7Improved
add AOQ to N2UQ on 4-bit ResNet-18N2UQ · ImageNet val ResNet-18 W4/A4top-1 accuracy (%): 72.9 -> 72.7Hurt
add AOQ to N2UQ on ResNet-34/50 at 3/4 bitsN2UQ · ImageNet val ResNet-34 W4/A4top-1 accuracy (%): 76.0 -> 76.0No clear effect
use AOQ on DeiT-T at 3-bit versus OFQLSQ+AOQ · ImageNet val DeiT-T W3/A3top-1 accuracy (%): 72.7 -> 72.3Hurt
use AOQ instead of OFQ on 2-bit DeiT-TLSQ+AOQ · ImageNet val DeiT-T W2/A2top-1 accuracy (%): 64.3 -> 66.5Improved
use AOQ instead of oscillation suppression throughout training on MobileNet-V2LSQ+AOQ · ImageNet val MobileNet-V2 W3/A3top-1 accuracy (%): 67.8 -> 69.1Improved