AI Paper Atlas

Research map / Video / Video generation

Text-to-Any-Skeleton Motion Generation Without Retargeting

Qingyuan Liu, Ke Lv, Kun Dong, Jian Xue, Zehai Niu, Jinbao Wang

ICCV 2025 · Video › Video generation · approach: Text-to-motion diffusion · 2 citations (OpenAlex)

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
add K-GCA to SR-VAE (ablation)SR-VAE · SkeleMotion-3D test (random skeleton to HumanML3D skeleton)FID: 0.065 -> 0.027Improved
add K-GCA to SR-VAE (ablation)SR-VAE · SkeleMotion-3D test (random skeleton to HumanML3D skeleton)Jitter Error: 9.594 -> 1.824Improved
use multi-head instead of single-head K-GCA (ablation)SR-VAE · SkeleMotion-3D test (random skeleton to HumanML3D skeleton)FID: 0.040 -> 0.027Improved
use multi-head instead of single-head K-GCA (ablation)SR-VAE · SkeleMotion-3D test (random skeleton to HumanML3D skeleton)Jitter Error: 2.935 -> 1.824Improved
use multi-head instead of single-head K-GCA (ablation)SR-VAE · SkeleMotion-3D test (random skeleton to HumanML3D skeleton)Skeleton Error: 12.294 -> 13.778Hurt
add residual vector quantization (ablation)SR-VAE · SkeleMotion-3D test (random skeleton to HumanML3D skeleton)FID: 0.165 -> 0.027Improved
add residual vector quantization (ablation)SR-VAE · SkeleMotion-3D test (random skeleton to HumanML3D skeleton)Skeleton Error: 19.726 -> 13.778Improved
use asymmetric (different encoder/decoder skeleton) reconstruction instead of symmetric (ablation)SR-VAE · SkeleMotion-3D test (random skeleton to HumanML3D skeleton)FID: 0.885 -> 0.027Improved
use asymmetric reconstruction instead of symmetric (ablation)SR-VAE · SkeleMotion-3D test (random skeleton to HumanML3D skeleton)Skeleton Error: 89.747 -> 13.778Improved
use MRO instead of rotation-based restoration (ablation)SR-VAE · SkeleMotion-3D test (random skeleton to HumanML3D skeleton)Jitter Error: 30.724 -> 2.084Improved
use MRO instead of rotation-based restoration (ablation)SR-VAE · SkeleMotion-3D test (random skeleton to HumanML3D skeleton)Skating Ratio: 0.193 -> 0.090Improved
add MRO over position-based restoration (ablation)SR-VAE · SkeleMotion-3D test (random skeleton to HumanML3D skeleton)Skeleton Error: 13.778 -> 0.00Improved

Earlier methods this paper compares with

Named baselines from earlier accepted papers in this paper's results tables: better than 2 of 2 on most shared results.

Matched by method name in results tables read by AI. Authors' own tables tend to favour the newer method, and a comparison can be missed when a method is renamed.

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy