AI Paper Atlas

Research map / Image generation / Super-resolution

Rethinking the Upsampling Process in Light Field Super-Resolution with Spatial-Epipolar Implicit Image Function

Ruixuan Cong, Yu Wang, Mingyuan Zhao, Da Yang, Rongshan Chen, Hao Sheng

ICCV 2025 · Image generation › Super-resolution · approach: Efficient lightweight super-resolution · 3 citations (OpenAlex)

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
replace original upsampling with SEIIFLF-InterNet · LFSSR average (x4, fixed-scale)PSNR (dB): 31.61 -> 32.12Improved
replace original upsampling with SEIIFLFT · LFSSR average (x2, fixed-scale)PSNR (dB): 38.85 -> 38.97Improved
replace original upsampling with SEIIF across eight encoderseight LFSSR encoders · LFSSR average (x2)PSNR (dB): [0.12, 0.39]Improved
replace original upsampling with SEIIF across eight encoderseight LFSSR encoders · LFSSR average (x4)PSNR (dB): [0.23, 0.51]Improved
add SIIF branch to SEIIF (ablation)SEIIF · SEIIF ablation (DistgSSR, x2)PSNR (dB): 38.92 -> 39.01Improved
add EIIF branch to SEIIF (ablation)SEIIF · SEIIF ablation (DistgSSR, x2)PSNR (dB): 38.87 -> 39.01Improved
add cross-branch feature interaction with two-step upsampling (ablation)SEIIF · SEIIF ablation (DistgSSR, x2)PSNR (dB): 38.96 -> 39.01Improved
use oriented line sampling instead of nearest sampling in EIIF (ablation)SEIIF · EIIF sampling ablation (x2)PSNR (dB): 38.95 -> 39.01Improved
use local sampling instead of nearest sampling in EIIF (ablation)SEIIF · EIIF sampling ablation (x2)PSNR (dB): 38.95 -> 38.94Hurt
use attention weighting instead of variance in oriented line sampling (ablation)SEIIF · EIIF sampling ablation (x4)PSNR (dB) and FLOPs: 32.53 -> 32.53; FLOPs 27.3 -> 60.3No clear effect
train with discrete scales U(1,4,0.5) instead of continuous U(1,4) (ablation)SEIIF arbitrary-scale · Training strategy ablation (x2)PSNR (dB): 38.35 -> 39.01Improved
add fine-tuning on target scale after multi-scale training (ablation)SEIIF fixed-scale · Training strategy ablation (x2)PSNR (dB): 38.95 -> 39.15Improved

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy