AI Paper Atlas

Research map / Federated learning and privacy / Personalized and heterogeneous FL

Soft Separation and Distillation: Toward Global Uniformity in Federated Unsupervised Learning

Hung-Chieh Fang, Hsuan-Tien Lin, Irwin King, Yifei Zhang

ICCV 2025 · Federated learning and privacy › Personalized and heterogeneous FL · approach: Non-IID federated learning · 1 citations (OpenAlex)

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
add projector distillation alone (ablation)FedAlignUniform · CIFAR10 cross-silo (K=10)linear probing accuracy: 80.84 -> 80.74No clear effect
add dimension-scaled regularization alone (ablation)FedAlignUniform · CIFAR10 cross-silo (K=10)linear probing accuracy: 80.84 -> 81.05Improved
add dimension-scaled regularization alone (ablation)FedAlignUniform · CIFAR10 cross-silo (K=10)negative uniformity loss: 3.79 -> 3.81Improved
add projector distillation on top of DSR (ablation)FedAlignUniform + DSR · CIFAR10 cross-silo (K=10)linear probing accuracy: 81.05 -> 81.32Improved
add projector distillation on top of DSR (ablation)FedAlignUniform + DSR · CIFAR10 cross-silo (K=10)negative uniformity loss: 3.81 -> 3.84Improved
add projector distillation on top of DSR (ablation)FedAlignUniform + DSR · CIFAR10 cross-silo (K=10)fine-tuning 1% accuracy: 69.77 -> 70.74Improved
add DSR when projector is removed (ablation)FedAlignUniform · CIFAR10 cross-silo (K=10) no projectorlinear probing accuracy: 73.16 -> 76.14 (+2.98)Improved
add DSR when projector is kept (ablation)FedAlignUniform · CIFAR10 cross-silo (K=10)linear probing accuracy: 80.84 -> 81.05 (+0.21)Improved
keep the projector (vs removing it) with DSR (ablation)FedAlignUniform + DSR · CIFAR10 cross-silo (K=10)linear probing accuracy: 76.14 -> 81.05Improved
use MSE instead of KL for projector distillation (ablation)SSD · CIFAR10 cross-silo (K=10)linear probing accuracy: 81.32 -> 81.88No clear effect
replace FedAlignUniform with SSDFedAlignUniform · CIFAR100 cross-device (K=50)linear probing accuracy: 43.03 -> 45.21Improved
replace FedAlignUniform with SSDFedAlignUniform · CIFAR100 to CIFAR10 transferlinear probing accuracy: 77.66 -> 78.48Improved

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy