AI Paper Atlas

Research map / 3D vision / Human pose estimation

Contact-Aware Refinement of Human Pose Pseudo-Ground Truth via Bioimpedance Sensing

Maria-Paola Forte, Nikos Athanasiou, Giulia Ballardini, Jan Ulrich Bartels, Katherine J. Kuchenbecker, Michael J. Black

ICCV 2025 · 3D vision › Human pose estimation · approach: Physics and sensor-based motion capture · 1 citations (OpenAlex)

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
add BioTUCH (2D + contact loss) refinementMulti-HMR · Self-contact dataset (arm region)PA-V2V (mm): 57.46 -> 50.21Improved
add BioTUCH refinementAiOS · Self-contact dataset (arm region)PA-V2V (mm): 72.24 -> 62.79Improved
add BioTUCH refinementTUCH · Self-contact dataset (arm region)PA-V2V (mm): 70.55 -> 63.99Improved
add BioTUCH refinementthree input methods · Self-contact dataset (arm region)PA-V2V: average 11.7% improvementImproved
add BioTUCH refinementthree input methods · Self-contact dataset (arm region)contact detection rate: average improvement of 31.60 percentage pointsImproved
add BioTUCH refinementthree input methods · Self-contact dataset (arm region)V-Distance (mm): average reduction of 15.39 mmImproved
add BioTUCH refinementthree input methods · Self-contact dataset (arm region)shoulder and elbow joint error: 0.36 mm and 0.50 mm degradationHurt
add BioTUCH refinementthree input methods · Self-contact dataset (arm region)wrist joint error: 8.85 mm improvementImproved
add contact loss on top of 2D loss (ablation)Multi-HMR + BioTUCH · Self-contact dataset (arm region)PA-V2V (mm): 77.41 -> 50.21Improved
add 2D loss alone to the baseline (ablation)Multi-HMR · Self-contact dataset (arm region)PA-V2V (mm): 57.46 -> 77.41Hurt
add 2D loss alone to the baseline (ablation)AiOS · Self-contact dataset (arm region)PA-V2V (mm): 72.24 -> 86.61Hurt
add 2D loss to the contact loss (ablation)Multi-HMR · Self-contact dataset (arm region)contact detection rate (%): 79.35 -> 78.34No clear effect

Earlier methods this paper compares with

Named baselines from earlier accepted papers in this paper's results tables: better than 1 of 1 on most shared results.

Matched by method name in results tables read by AI. Authors' own tables tend to favour the newer method, and a comparison can be missed when a method is renamed.

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy