AI Paper Atlas

Research map / Video / Video segmentation and tracking

AllTracker: Efficient Dense Point Tracking at High Resolution

Adam W. Harley, Yang You, Xinglong Sun, Yang Zheng, Nikhil Raghuraman, Yunqi Gu, Sheldon Liang, Wen-Hsuan Chu, Achal Dave, Suya You, Rares Ambrus, Katerina Fragkiadaki and 1 more

ICCV 2025 · Video › Video segmentation and tracking · approach: Learned optical flow estimation · 25 citations (OpenAlex)

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
use transformer temporal module instead of MLP-Mixer (ablation)AllTracker · Ablation validation set (6 datasets, Kubric 100k iters)delta_avg: 56.1 -> 56.8Improved
use transformer temporal module instead of ConvNext-1D (ablation)AllTracker · Ablation validation set (6 datasets, Kubric 100k iters)delta_avg: 54.6 -> 56.8Improved
use transformer temporal module instead of Conv-1D (ablation)AllTracker · Ablation validation set (6 datasets, Kubric 100k iters)delta_avg: 55.8 -> 56.8Improved
use motion relative to query frame (0->t) instead of adjacent frame (ablation)AllTracker · Ablation validation set (6 datasets, Kubric 100k iters)delta_avg: 56.4 -> 56.8Improved
add sinusoidal embedding of motion (ablation)AllTracker · Ablation validation set (6 datasets, Kubric 100k iters)delta_avg: 56.8 -> 54.8Hurt
use pretrained ConvNeXt backbone instead of scratch (ablation)AllTracker · Ablation validation set (6 datasets, Kubric 100k iters)delta_avg: 54.9 -> 56.8Improved
use pretrained ConvNeXt instead of BasicEncoder (ablation)AllTracker · Ablation validation set (6 datasets, Kubric 100k iters)delta_avg: 56.1 -> 56.8Improved
use 3 refinement blocks instead of 2 (ablation)AllTracker · Ablation validation set (6 datasets, Kubric 100k iters)delta_avg: 55.7 -> 56.8Improved
use 3 refinement blocks instead of 4 (ablation)AllTracker · Ablation validation set (6 datasets, Kubric 100k iters)delta_avg: 56.1 -> 56.8Improved
use correlation radius 4 instead of 5 (ablation)AllTracker · Ablation validation set (6 datasets, Kubric 100k iters)delta_avg: 55.5 -> 56.8Improved
use L1 loss instead of Huber loss (ablation)AllTracker · Ablation validation set (6 datasets, Kubric 100k iters)delta_avg: 54.9 -> 56.8Improved
train with ordered frames instead of shuffled (ablation)AllTracker · Ablation validation set (6 datasets, Kubric 100k iters)delta_avg: 56.3 -> 56.8Improved

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy