AI Paper Atlas

Research map / 3D vision / Depth and stereo

Deep Survival Analysis With Longitudinal X-Rays for COVID-19

Michelle Shu, Richard Strong Bowen, Charles Herrmann, Gengmo Qi, Michele Santacatterina, Ramin Zabih

ICCV 2021 · 3D vision › Depth and stereo · approach: Spike and event camera reconstruction · 9 citations (OpenAlex)

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
add time-dependent X-ray branch (ConvLSTM) to non-image model (ablation)Non-Image (ours) · COVID-19 clinical dataset: Admitconcordance error: 0.247 -> 0.198Improved
add time-dependent X-ray branch (ConvLSTM) to non-image model (ablation)Non-Image (ours) · COVID-19 clinical dataset: ICU Dischargeconcordance error: 0.439 -> 0.385Improved
add time-dependent X-ray branch (ConvLSTM) to non-image model (ablation)Non-Image (ours) · COVID-19 clinical dataset: Deathconcordance error: 0.278 -> 0.246Improved
add non-image LSTM branch to image-only model (ablation)Image-Only (ours) · COVID-19 clinical dataset: ICU Admitconcordance error: 0.408 -> 0.241Improved
use mini-batch stochastic gradient descent for DeepConvSurv instead of full-set gradient descentDeepConvSurv · COVID-19 clinical dataset: Deathconcordance error: 0.351 -> 0.435Hurt
obscure 100% of the X-ray image (ablation)Image+labs (ours) · COVID-19 clinical dataset: Admitconcordance error: 0.198 -> 0.268Hurt
obscure 100% of the X-ray image (ablation)Image+labs (ours) · COVID-19 clinical dataset: ICU Dischargeconcordance error: 0.335 -> 0.437Hurt
obscure 80% of the X-ray image (ablation)Image+labs (ours) · COVID-19 clinical dataset: Admitconcordance error: 0.198 -> 0.250Hurt
increase number of X-rays from k=1 to k=2 (ablation)Image+labs (ours) · COVID-19 clinical dataset: Admitconcordance error: 0.072Improved
increase number of X-rays from k=1 to k=2 (ablation)Image+labs (ours) · COVID-19 clinical dataset: ICU Dischargeconcordance error: 0.048Improved
increase number of X-rays from k=1 to k=2 (ablation)Image+labs (ours) · COVID-19 clinical dataset: Dischargeconcordance error: 0.006Improved
reduce mini-batch size from B>=20 to B=10 (ablation)Image+labs (ours) · COVID-19 clinical datasetconcordance errorHurt

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy