AI Paper Atlas

Research map / Vision-language and multimodal / Human and embodied modeling

Align, Attend and Locate: Chest X-Ray Diagnosis via Contrast Induced Attention Network With Limited Supervision

Jingyu Liu, Gangming Zhao, Yu Fei, Ming Zhang, Yizhou Wang, Yizhou Yu

ICCV 2019 · Vision-language and multimodal › Human and embodied modeling · approach: Scene graph generation · 105 citations (OpenAlex)

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
add alignment module (ablation)baseline model · NIH ChestX-ray localization, IoU 0.7mean localization accuracy: 0.23 -> 0.25Improved
add alignment module (ablation)CIA-Net · NIH ChestX-ray localization, IoU 0.7mean localization accuracy: 0.26 -> 0.28Improved
add contrast induced attention (CIA-Net) (ablation)baseline without alignment · NIH ChestX-ray localization, IoU 0.7mean localization accuracy: 0.23 -> 0.26Improved
add contrast induced attention (CIA-Net) (ablation)baseline with alignment · NIH ChestX-ray localization, IoU 0.7mean localization accuracy: 0.26 -> 0.28Improved
sample negatives by structural similarity instead of random (ablation)CIA-Net · NIH ChestX-ray localization, IoU 0.7mean localization accuracy: 0.27 -> 0.31Improved
sample negatives by structural similarity instead of always using canonical chest (ablation)CIA-Net · NIH ChestX-ray localization, IoU 0.7mean localization accuracy: 0.21 -> 0.31Improved
increase annotated images from 40% to 80% (ablation)CIA-Net · NIH ChestX-ray localization, IoU 0.7mean localization accuracy: 0.22 -> 0.31Improved
add 40% annotated images to unannotated-only training (ablation)CIA-Net · NIH ChestX-ray localization, IoU 0.7mean localization accuracy: 0.13 -> 0.22Improved
use CIA-Net instead of Z, Li [14] on identificationCIA-Net · NIH ChestX-ray classificationmean AUC: 0.80 -> 0.83Improved
use CIA-Net instead of Z, Li [14] at IoU 0.5CIA-Net · NIH ChestX-ray localization (80% annotated + 50% unannotated)mean localization accuracy: 0.27 -> 0.39Improved
use CIA-Net instead of Z, Li [14] at IoU 0.3CIA-Net · NIH ChestX-ray localization (80% annotated + 50% unannotated)mean localization accuracy: 0.49 -> 0.53Improved
use CIA-Net instead of own base model with no annotated data at IoU 0.7CIA-Net · NIH ChestX-ray localization (0% annotated)mean localization accuracy: 0.13 -> 0.13No clear effect

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy