Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| add exit-aware structured dropout (ablation) | early-exit ViT-B/16 baseline · CIFAR-100 exit s2 | accuracy: 75.61 -> 76.23 | Improved |
| add exit-aware structured dropout (ablation) | early-exit ViT-B/16 baseline · CIFAR-100 final exit s6 | accuracy: 89.40 -> 89.88 | Improved |
| add self-distillation without structured dropout (ablation) | early-exit ViT-B/16 baseline · CIFAR-100 exit s2 | accuracy: 75.61 -> 78.05 | Improved |
| add self-distillation without structured dropout (ablation) | early-exit ViT-B/16 baseline · CIFAR-100 final exit s6 | accuracy: 89.40 -> 87.73 | Hurt |
| add self-distillation without structured dropout (ablation) | early-exit ViT-B/16 baseline · CIFAR-100 exit s5 | accuracy: 88.85 -> 87.68 | Hurt |
| add self-distillation without structured dropout (ablation) | early-exit ViT-B/16 baseline · CIFAR-100 exit s4 | accuracy: 87.21 -> 86.51 | Hurt |
| combine structured dropout and self-distillation (full EnViT) (ablation) | early-exit ViT-B/16 baseline · CIFAR-100 exit s1 | accuracy: 60.48 -> 61.94 | Improved |
| combine structured dropout and self-distillation (full EnViT) (ablation) | early-exit ViT-B/16 baseline · CIFAR-100 exit s2 | accuracy: 75.61 -> 79.02 | Improved |
| add structured dropout on top of self-distillation (ablation) | EnViT-KD · CIFAR-100 final exit s6 | accuracy: 87.73 -> 89.94 | Improved |
| add self-distillation on top of structured dropout (ablation) | EnViT-SD · CIFAR-100 exit s2 | accuracy: 76.23 -> 79.02 | Improved |
| replace LGViT with EnViT | LGViT · CIFAR-100 | top-1 accuracy: 88.14% -> 89.23% | Improved |
| replace ViT-EE with EnViT | ViT-EE · ImageNet-1k | top-1 accuracy: 77.57% -> 80.45% | Improved |
Closest papers by meaning
- TinyViT: Fast Pretraining Distillation for Small Vision Transformers (ECCV 2022 · similarity 0.89)
- EdgeViTs: Competing Light-Weight CNNs on Mobile Devices with Vision Transformers (ECCV 2022 · similarity 0.88)
- You Need Multiple Exiting: Dynamic Early Exiting for Accelerating Unified Vision Language Model (CVPR 2023 · similarity 0.88)
- AdaViT: Adaptive Vision Transformers for Efficient Image Recognition (CVPR 2022 · similarity 0.88)
- Vision Transformers with Self-Distilled Registers (NeurIPS 2025 · similarity 0.87)
- Amortized-Precision Quantization for Early-Exit Vision Transformers (NeurIPS 2026 · similarity 0.86)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.