Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| add time-weighted image-space loss (WISL) to ControlNet training (ablation) | CoCoLIT · ADNI internal test | SSIM: 0.841 -> 0.865 | Improved |
| add constant-weight image-space loss (ISL) (ablation) | CoCoLIT · ADNI internal test | SSIM: 0.841 -> 0.870 | Improved |
| WISL vs constant-weight ISL when combined with LAS (ablation) | CoCoLIT · ADNI internal test | Balanced accuracy (%): 56.7% -> 62.3% | Improved |
| add Latent Average Stabilization at inference (ablation) | CoCoLIT · ADNI internal test | SSIM: 0.865 -> 0.896 | Improved |
| increase LAS samples m from 1 to 64 (ablation) | CoCoLIT · ADNI internal test | PSNR: 22.570 -> 24.135 | Improved |
| increase LAS samples m from 1 to 64 (ablation) | CoCoLIT · ADNI internal test | Balanced accuracy (%): 57.4% -> 62.3% | Mixed |
| decode averaged latent (LAS) instead of averaging 64 decoded images (ablation) | CoCoLIT · ADNI internal test | Balanced accuracy (%): 60.1% -> 62.3% | No clear effect |
| CoCoLIT vs best baseline on amyloid-positivity classification | MRI-to-PET synthesis · A4 external test | Balanced accuracy (%): 56.1% -> 79.8% | Improved |
| CoCoLIT vs best baseline on amyloid-positivity classification | MRI-to-PET synthesis · ADNI internal test | Balanced accuracy (%): 51.8% -> 62.3% | Improved |
| add WISL without LAS vs Base on balanced accuracy (ablation) | CoCoLIT · ADNI internal test | Balanced accuracy (%): 43.9% -> 57.4% | Improved |
| add LAS on top of WISL-trained model on SSIM (ablation) | CoCoLIT · ADNI internal test | HABC: 0.334 -> 0.522 | Mixed |
Closest papers by meaning
- DUAL-GLOW: Conditional Flow-Based Generative Model for Modality Transfer (ICCV 2019 · similarity 0.87)
- An Optimal Transportation Based Univariate Neuroimaging Index (ICCV 2017 · similarity 0.85)
- EMAD: Evidence-Centric Grounded Multimodal Diagnosis for Alzheimer's Disease (CVPR 2026 · similarity 0.84)
- Progression as Latent Drift: Generative Forecasting of Slow-Evolving Pathologies (ECCV 2026 · similarity 0.83)
- Simpler Diffusion: 1.5 FID on ImageNet512 with Pixel-space Diffusion (CVPR 2025 · similarity 0.83)
- Autoregressive Image Diffusion: Generation of Image Sequence and Application in MRI (NeurIPS 2024 · similarity 0.82)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.