Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| add Dual-Stream Encoder (ablation) | EndoIR baseline · SegSTRONG-C average | PSNR: 30.39 -> 31.96 | Improved |
| add Task Adaptive Embedding (ablation) | EndoIR baseline · SegSTRONG-C average | PSNR: 30.39 -> 31.40 | Improved |
| add Rectified Fusion Block (ablation) | EndoIR baseline · SegSTRONG-C average | PSNR: 30.39 -> 31.56 | Improved |
| add RFB on top of TAE+DSE (ablation) | EndoIR · SegSTRONG-C average | PSNR: 32.20 -> 32.36 | Improved |
| add RFB on top of TAE only (ablation) | TAE · SegSTRONG-C average | PSNR: 31.40 -> 31.51 | Improved |
| use both spatial and frequency embeddings in Dual-Domain Prompter (ablation) | Dual-Domain Prompter · SegSTRONG-C average | PSNR: 31.19 -> 32.36 | Improved |
| use FFT instead of wavelet transform in prompter (ablation) | Dual-Domain Prompter · SegSTRONG-C average | PSNR: 31.96 -> 32.36 | Improved |
| reduce NARB channel selection ratio from 1 to 0.5 (ablation) | Noise-Aware Routing Block · SegSTRONG-C average | SSIM: 87.05 -> 87.64 SSIM, 32.36 -> 32.23 PSNR | Mixed |
| select 0.75 of channels instead of 0.5 (ablation) | Noise-Aware Routing Block · SegSTRONG-C average | PSNR: 32.23 -> 32.02 | Hurt |
| NARB with gamma 0.5 for efficiency (ablation) | EndoIR · SegSTRONG-C | Params (M) and FPS: 28.2 -> 21.3 M params, 8.14 -> 11.18 FPS | Improved |
| EndoIR vs best baseline on CEC | EndoIR · CEC illumination correction | PSNR: 32.27 -> 32.65 | Improved |
| restore images with EndoIR before segmentation | DeepLabV3+ segmentation · SegSTRONG-C downstream | Dice: 95.47 -> 96.22 | Improved |
Earlier methods this paper compares with
Named baselines from earlier accepted papers in this paper's results tables: better than 1 of 1 on most shared results.
- PromptIR — PromptIR: Prompting for All-in-One Image Restoration (NeurIPS 2023) · better on 1 of 1 shared result
Matched by method name in results tables read by AI. Authors' own tables tend to favour the newer method, and a comparison can be missed when a method is renamed.
Closest papers by meaning
- Benchmarking Endoscopic Surgical Image Restoration and Beyond (CVPR 2026 · similarity 0.89)
- EndoBench: A Comprehensive Evaluation of Multi-Modal Large Language Models for Endoscopy Analysis (NeurIPS 2025 · similarity 0.85)
- Multi-view Masked Contrastive Representation Learning for Endoscopic Video Analysis (NeurIPS 2024 · similarity 0.83)
- Degradation-Aware Feature Perturbation for All-in-One Image Restoration (CVPR 2025 · similarity 0.83)
- A Unified Degradation-Robust Approach to SSL and UDA for 3D Medical Images (AAAI 2025 · similarity 0.82)